{"product_id":"phase2-utg-4000-ultrasonic-thickness-gauge-w-a-b-scan","title":"Phase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026B Scan","description":"\u003ch2\u003ePhase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026amp;B Scan\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Phase2+ UTG-4000 is a professional-grade, handheld ultrasonic thickness gauge engineered for demanding NDT applications where ordinary gauges fall short. Utilizing color waveform A-scan and time-based B-scan for absolute correctness, this state-of-the-art instrument is packed with useful features that allow operators to be fully confident in displayed values on the most critical applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThis multi-functional gauge offers everything from basic measurement and scan mode with Min\/Max viewing, to GO\/NO GO display, adjustable sound velocity, and thru-coating capabilities - consolidating what would otherwise require multiple instruments into a single, field-ready device. Operating on both pulse\/echo and echo\/echo methods with a dual element probe, the UTG-4000 is built to handle the full spectrum of thickness testing scenarios with precision and confidence.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"standard-markdown grid-cols-1 grid [\u0026amp;_\u0026gt;_*]:min-w-0 gap-3\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe UTG-4000 displays readings accurately in either inches or millimeters after a simple calibration to a known thickness or sound velocity, and its 2.4\" color screen makes waveform data easy to read in any lighting condition. Whether you're inspecting pipeline corrosion, structural steel, aerospace components, or coated assemblies, the UTG-4000 delivers the depth of measurement capability that quality and inspection professionals depend on.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor A-Scan \u0026amp; Time-Based B-Scan for Verification Confidence\u003c\/strong\u003e - Live color waveform A-scan and time-based B-scan display real-time signal data, giving operators the visual feedback needed to validate readings on the most demanding and critical measurement applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThru-Coating Measurement (Echo-Echo Mode)\u003c\/strong\u003e - Echo-Echo mode eliminates the need to remove paint or protective coatings, measuring substrate thickness in the 0.09\"–0.984\" range without surface preparation or disruption to protective layers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Measuring Range: 0.02\"–20.0\"\u003c\/strong\u003e - Standard pulse\/echo mode covers 0.02\" to 20.0\" dependent on probe and material, accommodating everything from thin-walled components to heavy structural members across metals, plastics, ceramics, and glass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGO\/NO GO Alarm with Dynamic Color Waveform Change\u003c\/strong\u003e - Configurable Min\/Max alarm thresholds trigger both an audible alert and a dynamic waveform color change on-screen, enabling fast pass\/fail decisions during scanning or high-volume inspection workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Display Modes for Advanced Analysis\u003c\/strong\u003e - Selectable display modes include digital thickness readout, A-scan\/waveform, Min\/Max capture, B-scan, and D-Value\/Reduction differential mode, providing the right data view for every inspection scenario.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Update Rate \u0026amp; Auto V-Path Correction\u003c\/strong\u003e - Update rate is user-selectable at 4Hz, 8Hz, or 16Hz to match scanning speed requirements, while automatic V-path correction ensures measurement accuracy across the full range without manual adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"222\"\u003e\n\u003ccol width=\"369\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUTG-4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principle\u003c\/td\u003e\n\u003ctd\u003eUltrasonic Pulse\/Echo \u0026amp; Echo\/Echo — Dual Element Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.4\" Color Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001\" \/ 0.01\" \/ 0.01 mm (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range – Standard Mode\u003c\/td\u003e\n\u003ctd\u003e0.02\"–20.0\" (10–145 mm), dependent on probe \u0026amp; material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range – Thru-Coating (E-E)\u003c\/td\u003e\n\u003ctd\u003e0.09\"–0.984\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.001\" (±0.05 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Error\u003c\/td\u003e\n\u003ctd\u003e±0.001\" (up to 0.984\") \/ ±0.007\" (up to 3.03\") \/ ±0.019\" (4\" and above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Velocity Range\u003c\/td\u003e\n\u003ctd\u003e0.0197–0.3937 in\/µs (500–9,999 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Modes\u003c\/td\u003e\n\u003ctd\u003eDigital Readout, A-Scan\/Waveform, B-Scan, Min\/Max Capture, D-Value\/Reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV-Path Correction\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eSelectable: 4 Hz, 8 Hz, 16 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh Rate\u003c\/td\u003e\n\u003ctd\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eMin\/Max with dynamic waveform color change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14°F–122°F (-10°C to +50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 5 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e2 × AA Alkaline Batteries (3V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 36 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.02\" × 2.99\" × 1.45\" (153 × 76 × 37 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.9 oz (280 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNIST Traceable Certificate of Calibration Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eItems Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePhase2+ UTG-4000 Base Instrument\u003c\/li\u003e\n\u003cli\u003eDual Element Probe\u003c\/li\u003e\n\u003cli\u003eCertificate of Calibration (NIST Traceable)\u003c\/li\u003e\n\u003cli\u003eOperation Manual\u003c\/li\u003e\n\u003cli\u003eCustom Carry Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Phase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026amp;B Scan User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/6991\/2348\/files\/Phase2_UTG-4000_Ultrasonic_Thickness_Gauge_w_A_B_Scan_User_Manual.pdf?v=1774614557\"\u003e\u003cimg alt=\"INSIZE ISHW-L20B Webster Hardness Tester Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/6991\/2348\/files\/PDF_image_100x100.png?v=1756409173\"\u003ePhase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026amp;B Scan User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Phase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026amp;B Scan Catalog\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/6991\/2348\/files\/Phase2_UTG-4000_Ultrasonic_Thickness_Gauge_w_A_B_Scan_Catalog.pdf?v=1774614584\"\u003e\u003cimg alt=\"INSIZE ISHW-L20B Webster Hardness Tester Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/6991\/2348\/files\/PDF_image_100x100.png?v=1756409173\"\u003ePhase2+ UTG-4000 Ultrasonic Thickness Gauge w\/A\u0026amp;B Scan Catalog\u003c\/a\u003e\u003c\/p\u003e","brand":"Phase2+","offers":[{"title":"Default Title","offer_id":53858733523228,"sku":"UTG-4000","price":1850.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/6991\/2348\/files\/Phase2_UTG-4000_Ultrasonic_Thickness_Gauge_w_A_B_Scan.png?v=1774614477","url":"https:\/\/precisionengineeringsupply.com\/products\/phase2-utg-4000-ultrasonic-thickness-gauge-w-a-b-scan","provider":"Precision Engineering Supply","version":"1.0","type":"link"}